|
|
|
|
Boiler
Automatic Steam Boiler
1.Noiseless operation. 2.The boiler inflammation ratio can reach up to 87% efficiency, safe and environment tal-friendly. 3.Special boiler body infrastructure, sufficient steam pressure within 4-5 minutes for operation. 4.Equipped with automatic computer system for water supply, ignition and stop automatically, safe and reliable.
|
|
Description |
Unit |
Type |
SJ-100E |
SJ-150E |
SJ-200E |
SJ-250E |
SJ-300E |
SJ-350E |
SJ-500E |
SJ-600E |
SJ-750E |
SJ-1000E |
1.Power Pressure :220V-380V &5 0-60 HZ
2.Specification listed is for reference only.Specification subject to change without prior notice.
3.The gas consumption values listed are based on 87% boiler efficiency with lower thermo (natural gas: 8900kcal/Nm³, barrel type 12000 kcal/Nm³), and the steam pressure of 10kg/cm² approximately.
4.Steam and fuel type of boiler options are available for your purpose. Pls contact us for further information. |
Hores Power |
BHP |
7 |
10 |
13 |
16.5 |
20 |
24 |
32 |
38 |
48 |
64 |
Max.working pressure |
Kgf/cm²(Mpa) |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Equivalent Evaporation |
KGH |
100 |
150 |
200 |
250 |
300 |
350 |
500 |
600 |
750 |
1000 |
Calorific Value |
Kcal/K(kw) |
53,900 |
80,850 |
107,800 |
134,750 |
161,700 |
188,650 |
269,500 |
323,400 |
404,250 |
53,900 |
Heating Surface |
m² |
2.7 |
3.0 |
3.78 |
4.2 |
5.4 |
5.64 |
8.65 |
8.65 |
9.0 |
9.96 |
Efficiency |
% |
87 |
87 |
87 |
87 |
87 |
87 |
87 |
87 |
87 |
87 |
Fuel Used |
GAS |
NATURAL GAS. LPG CYLINDRIC GAS |
Fuel Consumption Volume |
13A Natural |
89000kcal/Nm³ |
6.9 |
10.3 |
13.8 |
17.2 |
20.7 |
24.1 |
34.8 |
41.7 |
52.2 |
69.6 |
LPG Cylindric |
12000kcal/kg |
5.1 |
7.6 |
10.2 |
12.7 |
15.3 |
17.8 |
25.8 |
30.9 |
38.7 |
51.6 |
Elec. of Main Equipment |
KW |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
3 |
4 |
Weg of Product |
KG |
380 |
410 |
520 |
550 |
750 |
800 |
1,350 |
1,450 |
1,600 |
1,900 |
Dia. of Fuel’s Inlet |
13A |
mm |
20 |
20 |
25 |
32 |
32 |
40 |
40 |
40 |
40 |
50 |
LPG |
20 |
20 |
20 |
20 |
25 |
25 |
25 |
25 |
32 |
32 |
Dia. of Watering Inlet |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
25 |
26 |
Dia. of Steam Inlet & Outlet |
20 |
20 |
20 |
25 |
25 |
32 |
40 |
40 |
40 |
50 |
Dia. of Watering nd Drainage |
25 |
25 |
25 |
25 |
32 |
32 |
40 |
40 |
40 |
50 |
Dia. of Safe Cycliner’s Outlet |
20 |
20 |
25 |
25 |
32 |
32 |
40 |
40 |
50 |
60 |
Size of Boiler |
Width |
700 |
700 |
800 |
800 |
900 |
900 |
1,250 |
1,250 |
1,400 |
1,900 |
Length |
1,050 |
1,050 |
1,150 |
1,150 |
1,320 |
1,320 |
1,650 |
1,680 |
1,750 |
2,000 |
High |
1,600 |
1,700 |
1,760 |
1,860 |
2,050 |
2,150 |
2,200 |
2,200 |
2,200 |
2,400 |
|
Due to continuous improvement, all product specifications & appearance are subject to change without prior notice.
|
|
|
|
|
|
|